BAC Parts PLC3 SpareParts EN

Extrait du fichier (au format texte) :

PLC3

P PLC3 v01 EN
© 2024 Baltimore Aircoil International nv

3

Polairis condenser

2
4

i i
i i
i i
i

1.

Drift eliminators

2.

Spray branches

3.

Spray branch grommets

4.

Spray nozzles & nozzles grommets

5.

Coil(s)

6.

Upper pump piping

7.

Sleeve & clamps

1
Spray pump with volute

Dans la boutique



BAC SService EN General V00
BAC SService EN General V00
18/08/2024 - www.baltimoreaircoil.be
The SERVICE EXPERT for BAC Equipment Tailored SERVICES and SOLUTIONS for your BAC cooling towers and equipment YOUR DEDICATED PARTNER IN INNOVATIVE HEAT TRANSFER AND THERMAL STORAGE ORIGINAL SPARE PARTS AND FILL FOR AN EFFICIENT, SAFE AND YEAR ROUND RELIABLE OPERATION We develop, design, test and manufacture most parts, fills and eliminators in house to ensure the highest quality and performance and safest operation. Rely on BAC's expertise to optimize your cooling equipment UPGRADES AND NEW...

Eurovent CTI Article EN V01
Eurovent CTI Article EN V01
27/02/2025 - www.baltimoreaircoil.be
Eurovent Certita Certification (ECC) & Cooling Technology Institute (CTI) together provide industry certification of Cooling Towers and Closed Circuit Coolers covering the world. Performance certification is the basis for Endusers, consultants, Contractors, Manufacturers and Government to ensure correct investment in quality products. THE BASIC REQUIREMENT OF EVAPORATIVE COOLING EQUIPMENT & & Is rejecting the heat to the atmosphere of the process that needs to be cooled. At first sight an obvious...

BAC OriginalSpareParts SPARTv00EN
BAC OriginalSpareParts SPARTv00EN
18/08/2024 - www.baltimoreaircoil.be
Baltimore Aircoil BAC original spare parts ... ... keep your equipment fresh BAC original spare parts refresh your equipment to give you maximum confidence in the reliability of your cooling system. When you buy a BAC spare part you get more than just a component. You get a whole package of refreshing benefits that are only available from BAC : " Original performance for lowest system operating cost " Minimum downtime and maximum lifetime " Operational safety " Improved operation and maintenance...

BAC Retrofit PLC3 RetrofitOpportunities EN
BAC Retrofit PLC3 RetrofitOpportunities EN
18/08/2024 - www.baltimoreaircoil.be
RO_PLC3_EN_v00 PLC3 © 2024 Baltimore Aircoil International nv Retrofit Opportunities POLAIRIS CONDENSER Improve maintenance and accessibility Enhance operational safety Reduce sound emission Save water External platform with ladder & casing railing Access door opposite end* Additional intake & attenuation discharge Intake & discharge screens Intake & discharge attenuation Save energy and increase performance Increase reliability BCP automatic bleed control Clean out port * Only...

BAC SPLC3 SPolairis V02 EN 0
BAC SPLC3 SPolairis V02 EN 0
18/08/2024 - www.baltimoreaircoil.be
Highest capacity condenser with the most reliable lifetime efficiency Evaporative Condenser, model PLC3 UNMATCHED RELIABILITY MAXIMUM UPTIME AND LONGEVITY Multiple, independent Fan Systems provide optimal reliability and guarantee redundancy. Baltibond® Hybrid Coating comes as standard for maximum equipment life, with corrosion resistance equivalent to SST 304L. Dry operation possible. ULTRA COMPACT Polairis!" Evaporative Condenser ENERGY EFFICIENT UP TO 50% SAVINGS COMPARED TO CONVENTIONAL...

BAC Rigging PLC3 EN
BAC Rigging PLC3 EN
18/08/2024 - www.baltimoreaircoil.be
RPLC3-v00-EN PLC3 Evaporative Condensers RIGGING AND INSTALLATION INSTRUCTIONS About rigging and installation The BAC equipment should be rigged and installed as outlined in this bulletin. These procedures should be thoroughly reviewed prior to the rigging and operation to acquaint all personnel with the procedures to be followed and to assure that all necessary equipment will be available at the job site. Be sure to have a copy of the unit certified drawing available for reference. If you do...

BAC Parts PLC3 SpareParts EN
BAC Parts PLC3 SpareParts EN
18/08/2024 - www.baltimoreaircoil.be
PLC3 P PLC3 v01 EN © 2024 Baltimore Aircoil International nv 3 Polairis condenser 2 4 i i i i i i i 1. Drift eliminators 2. Spray branches 3. Spray branch grommets 4. Spray nozzles & nozzles grommets 5. Coil(s) 6. Upper pump piping 7. Sleeve & clamps 1 Spray pump with volute

BAC Maintenance PLC3 EN
BAC Maintenance PLC3 EN
18/08/2024 - www.baltimoreaircoil.be
MPLC3-v00-EN PLC3 Evaporative Condensers OPERATING AND MAINTENANCE INSTRUCTIONS Recommended maintenance and monitoring programme Baltimore Aircoil Company equipment needs to be properly installed, operated and maintained. Documentation of the equipment used, including a drawing, technical data sheet and this manual should be kept on record. To achieve long, trouble-free and safe operation, it is necessary to establish an operating plan including a programme of regular inspection, monitoring...
 

Datenblatt mcDSA E4
Datenblatt mcDSA E4
10/01/2011 - www.angst-pfister.com
mcDSA-E4 / mcDSA-E4-HC Motion Control · · · · · · · Very compact 4-quadrant controller to control brushtype, brushless DC-motors and linear motors Freely programmable with integral Motion Process Unit. Allows stand-alone operation and stand-alone networks CAN interface (DSP402) The controller has over-voltage, low-voltage and overtemperature monitoring With display "power", "status" and "error" The controller can be fixed by a hut-rail (35 mm) or fixing clips Three connection plugs are included...


01/03/2025 - www.malerba.fr
Résumé en cours de création pour ce fichier PDF


15/10/2024 - www.dow.com
Résumé en cours de création pour ce fichier PDF

RUBRIQUE 1510 – Arrêté du 5 août 2002 SIA – 25 rue ... - Souchier
RUBRIQUE 1510 – Arrêté du 5 août 2002 SIA – 25 rue ... - Souchier
29/03/2017 - www.souchier.fr
RUBRIQUE 1510  Arrêté du 5 août 2002 SIA  25 rue CONDORCET  95150 TAVERNY Page 1 sur 4 RUBRIQUE 1510  Arrêté du 5 août 2002 SIA  25 rue CONDORCET  95150 TAVERNY Page 2 sur 4 RUBRIQUE 1510  Arrêté du 5 août 2002 SIA  25 rue CONDORCET  95150 TAVERNY Page 3 sur 4 RUBRIQUE 1510  Arrêté du 5 août 2002 SIA  25 rue CONDORCET  95150 TAVERNY Page 4 sur 4

Solutions Outdoor de Profils Syst?mes : A chaque ext?rieur son ?quipement id?al !
Solutions Outdoor de Profils Syst?mes : A chaque ext?rieur son ?quipement id?al !
22/04/2025 - www.n-schilling.com
Résumé en cours de création pour ce fichier PDF


02/10/2024 - www.admin.fenwick.fr
Résumé en cours de création pour ce fichier PDF