White Paper Using A Specification Library For Humidification Projects

Extrait du fichier (au format texte) :

WHITE PAPER

USING A SPECIFICATION LIBRARY FOR
HUMIDIFICATION PROJECTS
EXECUTIVE SUMMARY
Architects, designers and other specifiers use 3-D models from product manufacturers  files that contain all the relevant data needed to make a decision about a building product. It's critical that these specifiers have access to online tools that allow them to research products and connect with building product manufacturers.
With more government agencies requiring traceability in building design, including access to the details of the equipment used, these models allow specifiers to provide this information and prove their accountability.
BIM content for all DriSteem's humidification systems are available for download online at a number of provider sites including SpecifiedBy, BIMobject, and ARCAT  delivering the fastest, simplest way to find and compare products during the research process.
These sites provide not only REVIT and other digital resources, but also specifications and other equipment details.
BIM adoption varies by country and by project type. The earliest adoption and largest adoption of BIM
is in the UK followed by Germany, Poland and France.

DriSteem Ultra-sorb® LV steam dispersion panel

1

INCORPORATING HUMIDIFICATION INTO DESIGNS
Importance of Humidification in Building Design
Proper humidification is extremely important for many applications and must be considered up front during the building design process. Factors to consider include the intent (humidification or cooling), the humidification load, available energy sources, quality of the supplied water, where the moisture will be dispersed, and the level and type of controls needed.
Failure to consider all factors may result in a system that operates inefficiently, doesn't meet the intended requirements, or can cause unintended consequences due to poorly managed moisture. With a good design, properly controlled humidification can promote health and safety, improve productivity, extend the life of materials, and enhance occupant satisfaction.
Here are some common uses of humidification:
"

Indoor Air Quality: Studies have shown that the optimum range for relative humidity (RH) is between 40-60%. Bacteria and viruses thrive in dry air where the relative humidity is less than 40%. Keeping the relative humidity under 60%
hinders the development of fungi, mites, and chemical interactions. Proper humidification can reduce occurrences of allergic rhinitis, respiratory infections, and asthma, which in turn reduces absenteeism.

"

Material Preservation: Many building materials, finishes,
furnishings, and artifacts are hygroscopic, meaning they

Dans la boutique



White Paper Using Dricalc To Confidently And Easily Specify And Select Humidification Systems
White Paper Using Dricalc To Confidently And Easily Specify And Select Humidification Systems
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
WHITE PAPER USING DRICALC® TO CONFIDENTLY AND EASILY SPECIFY AND SELECT HUMIDIFICATION SYSTEMS EXECUTIVE SUMMARY Humidification is an integral part of many of today's HVAC systems. The fundamental principles of humidification are well documented, but the intricacies of how humidification systems work within the context of a complex HVAC system, and the vast array of humidification options, can be daunting even for a seasoned HVAC Engineer. DriSteem is a world leader with over 50 years of expertise...

Hpas White Paper Adiabatic Basics
Hpas White Paper Adiabatic Basics
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
Adiabatic basics: Types, applications and benefits of adiabatic humidification Learn how adiabatic humidification can reduce cooling loads and energy costs Also included: t4ZTUFNEFTJHOFYBNQMFTXJUIQTZDISPNFUSJDT t)PXXBUFSRVBMJUZBGGFDUTQFSGPSNBODF BJSRVBMJUZ BOENBJOUFOBODFSFRVJSFNFOUT t'PDVTPOIJHIQSFTTVSFBUPNJ[JOHTZTUFNT by Lynne Wasner; and David Schwaller, Mechanical Engineer DRI-STEEM Corporation, Eden Prairie, mn Imagine a lazy, hot, August afternoon of your childhood, cicadas...

Whitepaper Ensuringhumidificationabsorption
Whitepaper Ensuringhumidificationabsorption
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
(U M I D IFI C ATI ON 7HITE 0A PER   4ECHNICAL DESIGN INFORMATION FROM )34%%- !VOIDING THE WET DUCT CALLBACK %NSURING HUMIDIFICATION ABSORPTION IN COMMERCIAL AND INDUSTRIAL APPLICATIONS #/.4%.43 2ELATIVE HUMIDITY AND TEMPERATURE $ISPERSING COLD WATER OR HOT STEAM -ANAGING WETNESS &ACTORS THAT AFFECT ABSORPTION 3IZING DISPERSION ASSEMBLIES "Y ,YNNE 7ASNER )34%%- #ORPORATION ! PROPERLY HUMIDIFIED BUILDING ENHANCES HEALTH AND COMFORT IMPROVES MANUFACTURING PROCESSES AND PRESERVES MATERIALS (OWEVER...

High Pressure System Data Center Case Study
High Pressure System Data Center Case Study
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
High-pressure system case study Data center humidification and cooling DriSteem system reclaims water from air handlers while it humidifies and cools a data center RESULTS " Maintains constant minimum humidity levels in a 130,000-square-foot server room with 35-foot ceilings " Reduces the building's cooling load by over 200 tons at peak demand " Reprocesses drain water from air handlers while producing no wastewater GUARANTEED SITE CONDITIONS This data center* provides colocation services, where...

Rogers Place Case Study
Rogers Place Case Study
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
Humidifying to Improve Ice Quality Rogers Place in Edmonton, Alberta Edmonton Oilers improve home ice by humidifying their arena IMPROVEMENTS IN BOTH ICE AND AIR " Improved ice quality from "three out of ten," according to 2016 Oilers player, to second-best the league according to a 2018 vote by players on all NHL teams. a in " Improved thermal comfort. Orange Blue Ice Crew remarked that they felt warmer after air moisture not temperature was increased in the arena. & NEW BUILDING, HIGH...

New Balance Sports Research Lab Case Study
New Balance Sports Research Lab Case Study
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
ENVIRONMENTAL CHAMBER PROVIDES ON-DEMAND CONDITIONS YEAR ROUND New Balance Sports Research Lab BOSTON, MA One of the most prominent brands in Boston Landing is New Balance. The neighborhood is home to the company's world headquarters, two retail stores, a fitness club, the TRACK at New Balance, and the New Balance Sports Research Lab. Measuring and improving performance The New Balance Sports Research Lab is equipped with 3D dynamic motion capture arrays and force plates that record athletes'...

Commercial Display Graphics Case Study 1116
Commercial Display Graphics Case Study 1116
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
High-pressure system case study Commercial display graphics DriSteem helps improve print consistency for a national leader in commercial display graphics RESULTS " Lowered the reject rate for large-format digital press output from 14 percent to 2.5 percent " Lowered the customer's electricity consumption enough to qualify for a significant utility rebate THE JOB Modernistic is one of the nation's leading suppliers of commercial display graphics and industrial OEM products. The company, headquartered...

Wts Handbk En
Wts Handbk En
24/07/2024 - d2tsmyh31fn7w8.cloudfront.net
WATER FUNDAMENTALS HANDBOOK First Edition ii DRISTEEM WATER FUNDAMENTALS HANDBOOK Water Fundamentals Handbook First Edition Steve Felber DRISTEEM WATER FUNDAMENTALS HANDBOOK iii Copyright © 2017 by DRI-STEEM Corporation All rights reserved. No part of this publication may be reproduced or transmitted, in any form or any means, without the written permission of the company. Printed and bound in the United States of America. First printing September 2017. DRI-STEEM Corporation 14949 Technology...
 

Zehnder Climate Ceiling Solutions, la nouvelle entité du groupe Zehnder dédiée à la commercialisation de solutions de plafonds chauffants rafraîchissants
Zehnder Climate Ceiling Solutions, la nouvelle entité du groupe Zehnder dédiée à la commercialisation de solutions de plafonds chauffants rafraîchissants
01/06/2023 - www.andresudrie.com
Information Presse | Juin 2023 ð< Radiateurs decoratifs ð< Ventilation double-flux ð< Plafonds climatiques ð< Clean Air Solutions Zehnder Climate Ceiling Solutions, la nouvelle entite du groupe Zehnder dediee a la commercialisation de solutions de plafonds chauffants rafraichissants Reglementations thermiques, decret tertiaire et explosion du cout de l'energie favorisent l'utilisation de solutions performantes dans les bureaux. Des 2013, pour accompagner la croissance de ce marche, le...

Un Systemuebersichtteil1
Un Systemuebersichtteil1
16/07/2024 - www.forster-profile.ch
110 30 24 62 60 34 50 70 88 88 RC3 50 85 150 92 34 50 92 88 Fenstervarianten Variantes des fenêtres Windows variants 70 40 34 70 50 92 88

E55W Brochure - Bobcat EMEA
E55W Brochure - Bobcat EMEA
09/12/2014 - www.bobcat.eu
E55W Compact Excavators E55W 1920 mm dozer blade 2000 mm dipperstick Boom load holding valve Dozer blade safety valve Fully adjustable air conditioning Adjustable suspension seat with high back and lumbar support Consoles with forwards/backwards adjustable displacement Steering column with adjustable angle Second auxiliary hydraulic line (Rotation piping) Fingertip auxiliary hydraulic controls Control console locks Hydraulic joystick controls Two-speed travel Storage compartment Horn Work and...

S770 Schranklader
S770 Schranklader
09/12/2014 - www.bobcat.eu
S770 | Compacte laders S770 | Technische specificaties Aanbouwdelen Nominale werkcapaciteit ISO 14397-1 Kiplast ISO 14397-1 Pompcapaciteit Pompcapaciteit (met optie hoog debiet) Systeemontlasting bij snelkoppelingen Max. rijsnelheid (laag bereik) Max. rijsnelheid (hoog bereik) 1569 kg 3137 kg 87,1 l/min 151 l/min 23,8 24,5 MPa 11,4 km/h 19,8 km/h Merk / Model Brandstof / Koeling Vermogen Maximum koppel bij 1600 tpm (SAE JI 995 bruto) Aantal cilinders Cilinderinhoud Brandstoftank Kubota /...

Les membres du r?seau des Fabricants Certifi?s Profils Syst?mes r?unis pour leur commission exclusive annuelle
Les membres du r?seau des Fabricants Certifi?s Profils Syst?mes r?unis pour leur commission exclusive annuelle
29/04/2025 - www.n-schilling.com
Résumé en cours de création pour ce fichier PDF

MARTEAUX PERFORATEUR ELECTRIQUE 2,5 KG
MARTEAUX PERFORATEUR ELECTRIQUE 2,5 KG
29/12/2010 - www.loxam.fr
0302 CONTEXTE RÉGLEMENTAIRE Les règles et normes ci-après sont applicables dans le cas d'une utilisation normale du matériel : · EN 50 144 conformément aux termes des réglementations 89/336/CEE, 98/37/CE. MONTAGE ET DÉMONTAGE DES OUTILS Consultez en complément la notice du constructeur PERFORATEUR ÉLECTRIQUE x 1 - S'assurer que l'appareil n'est pas branché. 2 - Choisir et mettre en place le mandrin approprié. DÉMONTAGE Bague de verrouillage 1 2 MONTAGE A - Mandrin SDS-plus · Perçage...