Photometrics data (PDF)

Extrait du fichier (au format texte) :

Luminaire Code LAVX 3W FR Name LAVX-1000 IP20 17x12V3W FR Line AGABEKOV Efficiency 36.63% 122.60 cd/klm Length Length 0.010000 m2 0.025000 m2 0.000250 m2 Asymmetrical 6.10

Measurement Code CLF1414/05-16I Name LAVX-1000 IP20 17x12V5WFROSTED Date 11-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 13 mm 10 mm

Lamp Code Number Position Total Flux C=315.00 G=15.00 Height Height

XENON 3W OP 12V 17 454.24 lm

Maximum value

Rectangular Luminaire Rectangular Luminous Area Horizontal Luminous Area Emitting area on Plane 0° Emitting area on Plane 90° Symmetry Type Measurement Distance Operator Temperature Humidity Notes Line AGABEKOV C.I.E. F UTE 5/5/5/6/6/6/6/6/6/6/6/6 0.36 G + 0.01 T

28 mm 25 0.025000 m2 0.000250 m2 0.026677 m2 180 722.33 lm 230.00 V 0.00 A LMT

Emitting area on Plane 180° Emitting area on Plane 270° Glare area at 76° Maximum Gamma Angle Measurement Flux Source Voltage Source Current Photocell

AC 25.00 °C 60.00 % XENON 12V 5W FROSTED Code XENON 3W OP 12V

Luminaire Lamps Name XENON RIGID LOOP LAMP 3W OP D DIN 5040 B NBN A31 BZ 5

Flux[lm] 26.72

Pow.[w] 3.0

Qta 17

1000mm x 13mm 90 Gamma Angle 180 120

180 0 105

30

105

270 90 C Halfplanes 180.0 90.0 0.0 270.0 75 30 75 90

60 60 60

90

ULOR DLOR

0.97 35.66 45 120 45

150 30 15 0 15

cd/klm 30

LITESTAR 7.S3

Dans la boutique



Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LU1X 3W FR Name LU1X-1000 IP20 17x12V3WFR Line AGABEKOV Efficiency 61.52% 152.28 cd/klm Length Length 0.020000 m2 0.023000 m2 0.000460 m2 Asymmetrical 6.10 Measurement Code CLF1414/05-15I Name LU1X-1000 IP20 17x12V 5W FROS Date 01-04-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 24 mm 20 mm Lamp Code Number Position Total Flux C=180.00 G=15.00 Height Height XENON 3W OP 12V 17 454.24 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code AMLN T5-1510 80W No Glass Name AMLN T5-1510 80W ASIM.WITH DF Line AGABEKOV Efficiency Maximum value 57.03% 328.13 cd/klm Length Length 0.139120 m2 0.000000 m2 0.000000 m2 Asymmetrical 0.00 Measurement Code CLF1414/07-02I Name AMLN T5-1510 80W ASIM.WITH DF Date 08-03-2007 Coordinate system Position 1500 mm 1480 mm C-G C=0.00 G=40.00 Width Width 120 mm 94 mm Lamp Code Number Position Total Flux Asymmetrical Height Height 1 6150.00 lm Rectangular Luminaire Rectangular Luminous Area...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code AML T5-1510 80W No Glass Name AML T5-1510 80W ASIM.WITH DFS Line AGABEKOV Efficiency Maximum value 57.03% 328.13 cd/klm Length Length 0.139120 m2 0.000000 m2 0.000000 m2 Asymmetrical 0.00 Measurement Code CLF1414/07-02I Name AML T5-1510 80W ASIM.WITH DFS Date 08-03-2007 Coordinate system Position 1500 mm 1480 mm C-G C=0.00 G=40.00 Width Width 120 mm 94 mm Lamp Code Number Position Total Flux 1 6150.00 lm Asymmetrical Height Height 105 mm 0 0.000000 m2 0.000000 m2 0.033656 m2 90...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LU4AL BB2800K Name LU4AL-1000 BB2800K Line AGABEKOV Efficiency Maximum value 48.15% 176.20 cd/klm Length Length 0.025000 m2 0.000000 m2 0.000000 m2 Measurement Code LU4AL BB2800K Name Rail LU4AL-1000 Date 01-00-0098 Coordinate system Position 1000 mm 1000 mm C-G C=0.00 G=0.00 Width Width 25 mm 25 mm Lamp Code Number Position Total Flux 1 306.00 lm Double Symmetrical Height Height 20 mm 0 0.000000 m2 0.000000 m2 0.006048 m2 180 306.00 lm 0.00 V 0.00 A Rectangular Luminaire Rectangular...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Réf. LFX-AC-1000 CL 3 W Nom LFX-AC-1000 XENON CLEAR 3 W 12V Archives AGABEKOV Rendement Valeur Maximum 100.00% 136.07 cd/klm Long. Long. 0.013020 m2 0.018600 m2 0.000280 m2 Asymétrique 0.00 OxyTech Mesure Réf. CLF1414/08-11I-BIS Nom LFX-AC-1000 XENON CLEAR 3 W 12V Date 07-02-2008 Syst. de Coordonnées C-G Position 1000 mm 930 mm C=0.00 G=15.00 Larg. Larg. 18 mm 14 mm Lampe Réf. Nombre Position Flux Total Asymétrique Haut. Haut. 17 418.00 lm Luminaire Rectangulaire Aire Lumineuse...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Réf. ARL-AC 10W 24V Nom ARL-AC-0910 24V/10W FROSTED Archives AGABEKOV Rendement Valeur Maximum 100.00% 857.39 cd/klm Long. Long. 0.084165 m2 0.000000 m2 0.000000 m2 Asymétrique 0.00 OxyTech Mesure Réf. CLF1414/08-19I-BF Nom ARL-AC-0910 24V/10W FROSTED Date 25-02-2008 Syst. de Coordonnées C-G Position 910 mm 905 mm C=0.00 G=30.00 Larg. Larg. 120 mm 93 mm Lampe Réf. Nombre Position Flux Total Asymétrique Haut. Haut. 15 909.00 lm Luminaire Rectangulaire Aire Lumineuse Rectangulaire...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code LT2X 3W CL Name LT2X-1000 IP20 17x12V 3W CL Line AGABEKOV Efficiency 45.08% 166.14 cd/klm Length Length 0.030000 m2 0.030000 m2 0.000900 m2 Asymmetrical 6.10 Measurement Code CLF1414/05-14I Name LT2X-1000 IP20 17x12V5WCLEAR Date 05-03-2005 Coordinate system C-G Position 1000 mm 1000 mm Width Width 33 mm 30 mm Lamp Code Number Position Total Flux C=180.00 G=10.00 Height Height XENON 3W CL 12V 17 530.74 lm Maximum value Rectangular Luminaire Rectangular Luminous Area Horizontal...

Photometrics data (PDF)
Photometrics data (PDF)
27/10/2010 - www.agabekov.com
Luminaire Code AGA A10 2800 Name AGA LED WHITE A10/2800°K-24V Line AGABEKOV 2009 Measurement Code CLF1414/09-05I-BF Name AGA LED WHITE A10/2800°K-BOMB Date 06-04-2009 Lamp Code Number Position Efficiency 100.00% Coordinate system C-G Total Flux Maximum value 4191.53 cd/klm Position C=330.00 G=2.00 Asymmetrical 1000 mm 995 mm Width Width 15 mm 15 mm Height Height
 

Notice de montage Volet Roulant GEPLAST GVR-ie sur ... - Lorillard
Notice de montage Volet Roulant GEPLAST GVR-ie sur ... - Lorillard
07/03/2018 - www.lorillard.fr
Sept. 2013 _ V2 Suivi des évolutions à la fin du dossier. Notice de montage Volet Roulant GEPLAST GVR-ie sur menuiserie PVC Pose en NEUF (dormants monoblocs) 1/11 Montage en 10 étapes 1/ 2/ 3/ 4/ 5/ 6/ 7/ 8/ 9/ 10 / Positionner le coffre sur un support. Présenter et clipper les pattes sur les embouts du coffre. Appliquer deux cordons de colle sur la sous-face. Positionner les embouts d étanchéité. Positionner le dormant sur la sous-face du coffre à la verticale. Visser les pattes sur...


01/03/2025 - www.malerba.fr
Résumé en cours de création pour ce fichier PDF

S?curit? et sant? au travail : FAUN s'engage aux c?t?s de ses collaborateurs
S?curit? et sant? au travail : FAUN s'engage aux c?t?s de ses collaborateurs
03/05/2025 - www.n-schilling.com
Résumé en cours de création pour ce fichier PDF


05/03/2025 - www.fundermax.at
Résumé en cours de création pour ce fichier PDF

Hager présente « épure et variations » la nouvelle collection luxe de kallysta
Hager présente « épure et variations » la nouvelle collection luxe de kallysta
25/11/2010 - www.n-schilling.com
COMMUNIQUÉ DE PRESSE / octobre 2009 Hager présente « épure et variations » la nouvelle collection luxe de kallysta Plus que de simples prises et interrupteurs, l'appareillage mural kallysta embellit les murs, révèle ou souligne une décoration, tout en se parant des dernières fonctions high-tech pour un confort personnalisé. Telle l'égérie du groupe Hager ­ acteur mondial de l'installation électrique de 1er rang ­, kallysta présente une somptueuse collection au summum du design,...

Ds 0491 Strata Heat Repair Guide La En
Ds 0491 Strata Heat Repair Guide La En
22/09/2024 - cdnmdm.laticrete.com
Globally Proven Globally Proven Construction Solutions Construction Solutions Wire Repair Kit On-Site Repair Kit Guide for STRATA_HEAT!" Wire Systems Warranty Disclaimer: This guide and the repair kit included have Heating Wire Construction been provided by LATICRETE, Inc. to aid in the repair of STRATA_HEAT!" Wire systems damaged on-site. LATICRETE cannot warranty the repair or guarantee the proper function of the heating system following a repair. LATICRETE recommends that all repair...